Digigram CANCUN 442-Mic User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 33
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
Click on to set the parameters of audio inputs.
Each slider allows adjusting the analog gain for an analog input from
0dB to + 55 dB, by 1 dB steps.
It is possible to adjust the level of several inputs at the same time, by
moving only one slider. To do so, press “Shift + Click” on each slider.
The cursor of the slider becomes purple. When all the selected sliders
are purple, just move one of them. All the sliders move at the same
time
The vu-meters display the signal level after the analog to digital
conversion. The peak-meter instantaneous value is displayed right
above the vu-meter.
To mute an input, click on the corresponding Mute icon . Mute is
ON when icon is red .
Input pad and 48V phantom power
Click on the icon on the top left of the ANALOG panel to
display the panel allowing to set Pad and 48V on the inputs.
Pad is a fixed attenuator stage (-30 dB) available on each
input, that can be enabled/disabled.
To enable the Pad on an input channel, click on the OFF
button on the right of PAD for the selected channel.
When Pad is enabled on a channel, the button is displayed as
follows:
Audio alignment when Pad is OFF.
Alignment when slider is set to 0 dB: -5.2 dBu -> 0dBfs
Alignment when slider set to 55 dB: -60.2 dBu -> 0dBfs
Audio alignment when Pad is ON.
Alignment when slider is set to 0 dB: +25.6 dBu -> 0dBfs
Alignment when slider set to 55 dB: -29.4 dBu -> 0dBfs
Set Pad to OFF when using microphones.
When using static microphones, it is necessary to enable the
14
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 32 33

Comments to this Manuals

No comments